h1. Wiki for NediImport plugin !nediimport.png! 
2 1 vongillus
3 16 vongillus
{{toc}}
4 16 vongillus
5 5 vongillus
h2. FAQ
6 5 vongillus
7 5 vongillus
h3. Why NediImport is not accessing directly the Mysql database?
8 5 vongillus
9 9 vongillus
NediImport is accessing the Nedi Web Server and run the requests with CURL.
10 5 vongillus
11 5 vongillus
Drawbacks:
12 5 vongillus
13 13 vongillus
* it can be slower than direct requests to the MySQL database (this is something we try to minimize in our code)
14 13 vongillus
* Usually the web interface changes much more than the MySQL database between NeDi versions, then maintenance is bigger for us developpers
15 5 vongillus
16 5 vongillus
Advantages:
17 5 vongillus
18 5 vongillus
* security/rights relies on NeDi itself
19 5 vongillus
* if you already have access to NeDi, then it works without giving rights/access to MySQL
20 5 vongillus
* it works for us because we don't have any rights to access the NeDi database
21 5 vongillus
22 7 vongillus
h3. NediImport and FusionInventory
23 7 vongillus
24 14 vongillus
NediImport tries to get useful information already available in NeDi and shows it in GLPI. So if you like NeDi or if you have an already running NeDi instance it can be quite interesting as you won't need for example SNMP access to the network devices.
25 7 vongillus
26 15 vongillus
NeDi is already running for years on sites with several thousands of nodes.
27 15 vongillus
28 15 vongillus
The best is to compare both projects NeDi and FusionInventory from their websites and see what best fit your needs.
29 8 vongillus
30 8 vongillus
I don't think it's a good idea to run both at the same time though! :)
31 7 vongillus
32 10 vongillus
h3. What is a virtual switch in NediImport?
33 10 vongillus
34 14 vongillus
When a managed switch sees more than one MAC address attached to one of its port, it means usually that a dumb switch (non managed) is connected to that port and that several nodes are connected. It can also be the case when you run virtual machines.
35 14 vongillus
In such a case, to be able to show this information in GLPI we create a fake switch, which we call "virtual switch" and we connect all theses nodes to this virtual switch. This virtual switch gets its name from the parent switch and the port number on which it is connected.
36 1 vongillus
37 20 seinlc
h2. Pages
38 19 seinlc
39 24 seinlc
h3. Howto
40 1 vongillus
41 24 seinlc
* [[How to setup NediImport plugin]]
42 24 seinlc
* [[How to upgrade NediImport plugin?]]
43 1 vongillus
44 24 seinlc
h3. Help
45 24 seinlc
46 24 seinlc
* [[Configuration help]]
47 24 seinlc
48 24 seinlc
h3. Others
49 24 seinlc
50 24 seinlc
* [[What can NediImport plugin for you?]]
51 24 seinlc
52 24 seinlc
h3.